Completed Certificates
T-one, as a certified telematics accessory, has obtained FCC and CE certifications, a level of regulatory compliance rarely seen among comparable accessories. These certifications confirm electromagnetic compatibility and safety compliance, enabling reliable integration with vehicle tracking and logistics monitoring systems in regulated markets.
T-one collects the temperature and humidity (T-one PN:02) of the environment and transmits the data via BLE to trackers or BLE hub. It is designed for the demands of the environmental monitoring industry to resolve losses caused by unexpected and unfriendly temperature changes.
Features
BLE 5.1
It can be used for data broadcasting and wireless configuration
High accuracy
Accuracy of ± 0.1~0.7℃ for temp.;
Accuracy of ± 0.3~0.7% RH for humi.
Frequent data broadcasting
Broadcasting data every 10s by default (configurable)
BLE 5.1
It can be used for data broadcasting and wireless configuration
High accuracy
Accuracy of ± 0.1~0.7 ℃ for temp;
Accuracy of ± 0.3~0.7% RH for humi
Frequent data broadcasting
Historical data storage
Can store up to 15,000 temperature and humidity data in sensors to be extracted by phone
Historical data storage
Can store up to 15,000 temperature and humidity data in sensors to be extracted by phone
Wide transmission range
Operating distance up to 200m (open field)
Wide range of measuring temperature
Probe measuring between
-40℃ ~ +125℃ (-40℉ to 257℉) (T-one)
-40℃ to 130℃ (-40℉ to 266℉) (T-one PN:02)
Wide transmission range
Operating distance up to 200m (open field)
Wide range of measuring temperature
Probe measuring between
-40℃ ~ +125℃ (-40℉ to 257℉) (T-one)
-40℃ to 130℃ (-40℉ to 266℉) (T-one PN:02)
FOTA
Firmware upgrade Over-the-Air
FOTA
Firmware upgrade Over-the-Air
Technical Specifications
General Specifications
Waterproof: IP67
Dimensions: 59.9mm × 40.0mm × 14.6mm(2.36” × 1.57” × 0.57”)
Weight
- 59g (2.4oz, battery and 1-meter probe included)
- 36g (1.50 oz, probe not included)
Battery: Non-replaceable CR2477 battery (1000mAh)
Operating temperature
- Housing: -30℃ ~ +80℃ (-22°F ~ 176°F),
- Probe: -40℃ to 125℃ (-40℉ to 257℉) (T-one);
-40℃ to 130℃ (-40℉ to 266℉) (T-one PN:02)
Temperature accuracy
- T-one:
± 0.7°C (-40°C to -25°C);
± 0.5°C (-25°C to 0°C);
± 0.3°C (0°C to 35°C);
± 0.1°C (35°C to 45°C);
± 0.3°C (45°C to 90°C);
± 0.7°C (90°C to 125°C).
Long-term drift <0.02℃ / Year) - T-one PN: 02
± 0.3℃ (-40℃ to 90℃);
± 0.7℃ (90℃ to 130℃).
Long-term drift <0.03℃ / Year)
Open field transmission range (BLE 5.1): Up to 200m (656 fts) @ 4 dBm
TFT Eddystone: Yes
Eddystone UID: Yes
Beacon: Yes
Battery Life
1800 Days @ Interval: 10s & TX=0 dBm & Temperature = 25℃ &
Temperature on (Default Off) Only use TFT Eddystone (Default Enable)
1650 Days @ Interval: 10s & TX=4 dBm & Temperature = 25℃ &
Temperature on (Default Off)
1450 Days @ Interval: 5s & TX=0 dBm & Temperature = 25℃ &
Temperature on (Default On)
1200 Days @ Interval: 5s & TX=4 dBm & Temperature = 25℃ &
Temperature on (Default On)
Certification
CE, FCC