It collects the temperature and humidity of the environment and transmits the data via BLE to trackers or BLE hub, then transmitted to server finally. Designed for the demands of the environmental monitoring industry to resolve losses caused by unexpected and unfriendly temperature and humidity changes.
It can be used for data broadcasting and wireless configuration
Accuracy of ± 0.2 ℃ for temp, and 2% RH for humi
Broadcasting data every 60s by default (configurable)
It can be used for data broadcasting and wireless configuration
Accuracy of ± 0.2 ℃ for temp, and 2% RH for humi
Broadcasting data every 60s by default (configurable)
10 seconds reporting intervals it can last up to 6 years
10 seconds reporting intervals it can last up to 6 years
Operating distance up to 300m (open field)
Operating between -30℃ ~ +80℃ (-22°F ~ 176°F)
Operating distance up to 300m (open field)
Operating between -30℃ ~ +80℃ (-22°F ~ 176°F)
Alerts sent when device is exposed to light for notifying users when parcels or luggage been open.
Can store up to 15,000 temperature and humidity data in sensors to be extracted by phone
Alerts sent when device is exposed to light for notifying users when parcels or luggage been open.
Can store up to 15,000 temperature and humidity data in sensors to be extracted by phone
Waterproof: IP65
Dimensions: 69.75mm * 52.6mm * 19.8mm (0.23 “* 0.17” * 0.06 “)
Weight: 35g (1.23oz, battery included)
Battery: replaceable CR2477 battery (1000mAh)
Operating temperature: -30℃ ~ +80℃ (-22°F ~ 176°F)
Temperature accuracy (0-60 ℃) : ± 0.2 ℃ (Typical long-term drift <0.02 ° C / year)
Humidity accuracy (10% -90%): ± 2% RH (long-term drift rate <0.25% RH / Y)
Transmission range: up to 300m (open field)
Others: Front light sensor
8 years every 60 minutes 5 years every 10 seconds
TSTH1-B will be a legacy model. For new projects, we recommend T-one, which is fully compatible and actively produced.
| Feature | TSTH1-B | T-one (with Probe) |
|---|---|---|
| Sensor type | Internal temperature sensor | External temperature probe |
| Temperature detection | Ambient / limited range | Wider temperature differential detection |
| Measurement position | Fixed (device body) | Flexible, probe-based placement |
| Use case suitability | Standard temperature monitoring | High temperature variation environments |
| Deployment flexibility | Limited | High – adaptable to complex scenarios |
| Recommended for | Existing deployments | New projects & demanding applications |
Unlike TSTH1-B, which relies on an internal sensor, T-one supports an external temperature probe, allowing measurements in locations where temperature differences are more extreme or where ambient readings are not sufficient.
This makes T-one better suited for applications requiring accurate monitoring across wider temperature gradients.